The Maxx Super Silence Exhaust Fan from the Maxx line is a state-of-the-art model that redefines the concept of efficient ventilation and quiet operation in ventilation systems.
Designed with the exclusive Silence Acoustic Design technology, it delivers maximum performance with minimum noise.
Outdoor Air Intake: Compatible with Filbox line filters, allowing high-quality outdoor air intake.
High Pressure and Airflow: Ideal for installation in long duct systems, providing efficient in-line support with high pressure and high airflow.
Product Overview

Aviation-Inspired Technology:
Inspired by commercial aircraft cabins, Silence Acoustic Design technology combines sound-absorbing materials with intelligent aerodynamic structural shapes. This innovation significantly reduces vibrations and noise generated by the airflow and the motor-fan assembly, ensuring nearly imperceptible operation.
Key Features:
- Inline exhaust fan with an ultra-low noise level;
- Exclusive SILENCE ACOUSTIC DESIGN technology;
- Diameters from 125 to 315mm;
- Airflows from 245 to 2000 m³/h;
- Maximum pressures from 17 to 70 mmWG;
- Available in 220V;
- White epoxy-painted or galvanized finish;
- Patent pending.
Optional Features
- Anti-Mold
- Silencius
- Timer
Technical Specifications
| MAXX SUPER SILENCE | MODEL | ||||||
|---|---|---|---|---|---|---|---|
| 125 | 150 | 200 | 250 | 315 | |||
| Frequency | 50 / 60 Hz | ||||||
| Maximum Airflow | m³/h | Min | 245 | 475 | 660 | 1083 | 1620 |
| Max | 410 | 710 | 996 | 1400 | |||
| CFM | Min | 144 | 280 | 388 | 637 | 953,37 | |
| Max | 241 | 418 | 586 | 824 | |||
| Maximum Pressure | mmWG | Min | 17 | 28 | 29 | 37 | 43 |
| Max | 26 | 38 | 39 | 50 | |||
| In. W.G | Min | 0,669 | 1,102 | 1,142 | 1,457 | 1,692 | |
| Max | 1,024 | 1,496 | 1,535 | 1,969 | |||
| Single-Phase Voltage [V] | 220 V | ||||||
| Total Power Consumption [W] | 220 V | Min | 51,452 | 46,774 | 46,774 | 154,357 | 257,261 |
| 220 V | Max | 72,033 | 65,484 | 65,484 | 210,486 | 364,843 | |
| Sound Pressure Level [dB] * | Min | 22 | 26 | 21 | 27 | 29 | |
| Max | 23 | 30 | 27 | 32 | 35 | ||
| Ambient Sound Pressure Level – Leq [dBA] ** | Min | 43 | 43 | 44 | 54 | 57 | |
| Max | 47 | 48 | 49 | 59 | |||
| Duct [in] | 5″ | 6″ | 8″ | 10″ | – | ||
| Weight | Kg | 7 | 7 | 7,5 | 14 | 24 | |
| lbs | 15,432 | 15,432 | 16,534 | 30,864 | 52,910 | ||
** Specifications for 220V/60Hz. Sound pressure level perceived in the environment, radiated at 3m in a free field, with ducts at the intake and discharge.








| Model | Dimensions [mm] | ||||||
|---|---|---|---|---|---|---|---|
| A | ØB | ØC | D | E | F | ØG | |
| MAXX SS 125 | 313 | 308 | 124 | 612 | 623 | 591 | 7,5 |
| MAXX SS 150 | 149 | ||||||
| MAXX SS 200 | 199 | ||||||
| MAXX SS 250 | 378 | 373 | 251 | 767 | 757 | 725 | |
| MAXX SS 315 | 455 | 450 | 313 | 942 | 932 | 901 | |
Modelos
MAXX SS 125
MAXX SS 150
MAXX SS 200
MAXX SS 250
MAXX SS 315
Download Center
Frequently Asked Questions
The main function of an exhaust fan is to extract gases and vapors from the environment, providing indoor air renewal.
When purchasing your exhaust fan, remember to check the unit’s dimensions and the manufacturer’s installation guidelines.
To increase airflow, it is necessary to install one exhaust fan next to another, duplicate the ductwork, or use an exhaust fan with a higher airflow capacity. To increase pressure, the exhaust fans must be installed one behind the other.
The installation of an exhaust fan must comply with NBR 16401/2008, both in terms of performance, dimensions, and construction characteristics.
A good exhaust system should always provide better air quality while meeting the needs of your environment. If you are unsure which product is best for you, you can contact one of our specialists. We have a specialized team with the technical expertise needed to help you make the best choice.
Energy consumption depends largely on the type of exhaust fan and the environment in which it will be installed.
Sicflux exhaust fan lines offer the advantage of providing air quality and thermal comfort without increasing your energy costs.
Exhaust fans can be installed in any room where the goal is to provide indoor air renewal, with greater benefits when installed in kitchens and bathrooms. In addition, they are essential for larger environments, such as industrial facilities and commercial establishments.
Yes, the exhaust fan can remain running continuously without reducing its expected service life.
The difference is the airflow, which is the amount of air moved by the product. The higher this number, the greater the volume of air it moves, resulting in greater indoor air renewal.