The FH Line was designed to improve air quality in enclosed spaces, offering compact and high-efficiency units that are an ideal solution for exhaust applications in confined areas. In general, exhaust fans help eliminate odors and impurities in spaces with little or no ventilation, promoting air renewal and ensuring greater comfort for occupants.
The FH version without filter features high-pressure and high-flow radial motors. Operating temperature range: (-40°C to +65°C). Built with reinforced sheet metal, these units have special sealing on joints and access covers, providing greater resistance and durability.
About the Product

Main Features:
Construction Design:
✲ Direct-drive motor with integrated bearings, eliminating belts and pulleys;
✲ Internal electrical box with side access for easier installation and maintenance;
✲ Versatile installation, allowing vertical or horizontal mounting options;
✲ Thermal overload protector.
Operation:
✲ Low energy consumption;
✲ Quiet operation;
✲ High airflow and pressure (radial fan).
Equipment:
✲ Models available in sizes from 100 to 400 mm;
✲ Models above 250 mm available exclusively with rectangular inlet.
Operating Temperature: -40°C / 65°C
Technical Specifications
| MODEL | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| 100 | 125 | 150 | 200 | 250 | 315 | 355 | 400 | ||
| Maximum Airflow | m³/h | 245 | 343 | 644 | 970 | 1548 | 2048 | 2491 | 3447 |
| CFM | 144,1 | 201,7 | 378,7 | 570,4 | 910,2 | 1204,2 | 1464,7 | 2026,8 | |
| Frequency | Hz | 50 / 60 | |||||||
| Total Input Power | W | 73,9 | 70,2 | 88,9 | 104,8 | 170,3 | 308,7 | 171,2 | 454,7 |
| Noise Level | dBA | 55 | 55 | 57 | 60 | 63 | 65 | 61 | 63 |
| Single-Phase Voltage | V | 220 | |||||||
| Maximum Pressure | mmCA | 38,0 | 40,0 | 43,0 | 65,0 | 53,0 | 55,0 | 43,0 | 57,0 |
| Duct | inch | 4 | 5 | 6 | 8 | 10 | 12 | 14 | 16 |
| Weight | KG | 10 | 10 | 12 | 16 | 25 | 28 | 33 | 42 |
*Specifications for 220 V / 60 Hz. Sound pressure level measured at 3 m (9.8 ft) in a free field, with ducts connected to both the inlet and outlet. 1/3 octave band: 2.5 kHz.
Performance Curves


Modelos
FH 100 a 200
| MODEL | Dimensions (mm) – Round Inlet | |||
|---|---|---|---|---|
| A | B | C | D | |
| FH 100 / 125 | 98/124 | 562 | 390 | 185 |
| FH 150 | 149 | 722 | 429 | 203 |
| FH 200 | 198 | 760 | 448 | 225 |


FH 250 a 400
| Model | Dimensions [mm/in] – Rectangular Inlet | ||||
|---|---|---|---|---|---|
| B | C | D | E | F | |
| FH 250 | 890 | 573 | 289 | 470 | 190 |
| FH 315 | 937 | 574 | 339 | 470 | 240 |
| FH 355 | 906 | 638 | 387 | 530 | 290 |
| FH 400 | 1087 | 720 | 425 | 590 | 320 |


Download Center
FAQ
It is very important to properly size the air supply unit according to the room’s dimensions (volume and shape), following the technical recommendations of standard NBR 16401-2008.
A good air supply unit should always provide better air quality, meeting the specific needs of your space. If you’re not sure which product is best for you, feel free to reach out to one of our specialists. We have a dedicated team with the technical expertise to help you make the best choice.